From the FAQ at http://www.modbus.org:

MODBUS® Protocol is a messaging structure developed by Modicon in 1979, used to establish master-slave/client-server communication between intelligent devices. It is a de facto standard, truly open and the most widely used network protocol in the industrial manufacturing environment. It is implemented by hundreds of vendors on thousands of different devices in order to transfer discrete/analog I/O and register data between control devices.

Traditional PWM vs Morningstar’s TrakStar™ MPPT Technology

MSView

Tech Support Policy

TriStar MPPT Processor A Firmware Update

v32b Firmware and above addresses EEprom access bugfix causing watchdog trip and subsequent lowside FET turn on.  This issue is generally limited to Controllers installed in applications utilizing all, or most, of the following items in the design.  -High I/O of Communications, -Read/Write of vb_ref register (0x0033), -Read/Write of ib_ref register (0x0058), -Write of battery current limit (0xE01D), -Coil command restart of controller, -48V Systems, -Oversized Arrays.  The following link provides instructions on updating firmware:   https://www.youtube.com/watch?v=J6Duwr5Tl-w&t=10s

 